1. Home
  2. Blog
  3. How many types of dry transformers are there?

How many types of dry transformers are there?

    Get Free Solution

    The company has strong technical strength, has more than 50 professional and technical personnel, and has formed a technical team with technicians, engineers, and chief engineers responsible for each level.

    Nantong Dazheng Electric Transformer Factory

    Nantong Dazheng Electric Co., Ltd. is located in Nantong City, Jiangsu Province. Founded in 2005, Dazheng Electric is a professional high-tech manufacturing enterprise integrating R&D, manufacturing, sales and service. It mainly produces various types of oil-immersed power transformers, dry-type transformers, European box transformers, American box transformers and other transformers. We use modern scientific management, advanced production testing equipment and complete product after-sales service to ensure that the transformer production process complies with the international ISO9001 quality management system and ISO40001 environmental management system certification.

    Nantong Dazheng Electric insists on being customer-centric and providing customers with high-quality, competitively priced products to achieve a win-win situation. With advanced management, first-class technology, reliable quality and perfect service, we provide high-quality power transmission and distribution equipment to global customers.

    People also ask

    What are the series of dry-type transformers in Dazheng?

    1  SCB10 series resin insulated dry-type transformer

    Transformer dimensions

    standard:

    Capacity range: 30~2500kVA

    Voltage level 0~35kV

    Voltage regulation mode: non-excitation voltage regulation or on-load voltage regulation

    Tap range: ±5%, ±2×2.5%, ±4×2.5%

    Frequency: 50Hz or 60Hz

    Number of phases: three-phase or single-phase

    Connection group label: Yyn0, Dyn11 or others

    Short circuit impedance: standard impedance

    When the altitude is less than 1,000 meters and the ambient temperature is lower than 40°C. When the above usage conditions are exceeded, corresponding quota adjustments should be made according to the standards.

    Maximum temperature rise: 100k

    Cooling method: self-cooling (AN) or air-cooling (AF)

    Protection level: IP00, IP20, IP23

    Insulation level: F level

    Characteristics of dry-type transformers

    1. The high voltage winding is made of enameled copper wire or double glass fiber wrapped flat copper wire, and the low voltage winding is made of copper foil. The high-voltage winding is filled with glass fiber mat, and imported epoxy resin without filler is cast in a vacuum state. After curing, it forms a solid whole with good mechanical strength, small partial discharge and high reliability.
    2. It is flame retardant, explosion-proof, does not pollute the environment, and can be installed in load centers.
    3. The coil does not absorb moisture, and the core and clamps have been treated with special processes to operate in 100% relative humidity and other harsh environments. Intermittent operation does not require dehumidification treatment.
    4. High resistance to short circuit and lightning impact.
    5. The resin insulation layer inside and outside the coil is thin and has good heat dissipation performance. The cooling method generally adopts air natural cooling (AN). An air cooling system (AF) can be configured for transformers of any protection level.
    6. Low loss, good power saving effect, economical operation and maintenance-free.
    7. Small size, light weight, small footprint and easy installation.

    2  SC(B)12 type dry type transformer

    Low loss: The no-load loss of the product is more than 20% lower than that of the SCB10 model, with excellent energy saving effect and maintenance-free.

    Low noise: The product noise level is more than 10-15 decibels lower than the current professional standards.

    Low partial discharge: can be controlled below 5PC. The coil cast body has a tight solidified structure, is flame retardant and explosion-proof, and does not pollute the environment.

    High mechanical strength: can withstand sudden short-circuit electric force without damage.

    Main performance parameters

    Model  Rated capacity Connection group label Voltage combination No-load loss (w) Load loss (w)  No-load current (%) Short-circuit resistance (%))
    HV  tap range LV
    SCB12-30 30  

     

     

     

     

     

     

    Yyn0

    0r

    Dyn11

     

     

     

     

     

     

     

    10

    6.3

    6

     

     

     

     

     

     

     

     

    ±5%

    ±2×2.5%

     

     

     

     

     

     

     

     

    0.4

    150 710 2.4  

     

     

     

     

     

    4.0

    SCB12-50 50 215 1000 2.4
    SCB12-80 80 295 1380 1.8
    SCB12-100 100 320 1570 1.8
    SCB12-125 125 375 1850 1.8
    SCB12-160 160 430 2130 1.6
    SCB12-200 200 495 2530 1.6
    SCB12-250 250 575 2760 1.4
    SCB12-315 315 705 3470 1.4
    SCB12-400 400 785 3990 1.2
    SCB12-500 500 930 4880 1.2
    SCB12-630 630 1070 5880 1.0
    SCB12-800 800 1215 6960 1.0  

     

     

    6.0

    SCB12-1000 1000 1415 8130 1.0
    SCB12-1250 1250 170 9690 1.0
    SCB12-1600 1600 160 11730 1.0
    SCB12-2000 2000 2440 14450 0.8
    SCB12-2500 2500 2880 17170 0.8

    3  SCB(13) dry type transformer

    Low loss: The no-load loss of the product is more than 30% lower than that of the SCB10 model. It has excellent energy saving effect and is maintenance-free.

    Low noise: The product noise level is more than 10-15 decibels lower than the current professional standards.

    Low partial discharge: can be controlled below 5PC. The coil cast body has a tight solidified structure, is flame retardant and explosion-proof, and does not pollute the environment.

    High mechanical strength: can withstand sudden short-circuit electric force without damage.

    Data Sheet

    Model  Rated capacity Connection group label Voltage combination No-load loss (w) Load loss (w)  No-load current (%) Short-circuit resistance (%))
    HV  tap range LV
    SCB13-30 30  

     

     

     

     

     

     

    Yyn0

    Or

    Dyn11

     

     

     

     

     

     

     

    11

    10.5

    10

    6.6

    6

     

     

     

     

     

     

     

     

    ±5%

    ±2×2.5%

     

     

     

     

     

     

     

     

    0.4

    135 710 2.3  

     

     

     

     

     

    4.0

    SCB13-50 50 190 1000 2.2
    SCB13-80 80 260 1380 1.7
    SCB13-100 100 290 1570 1.7
    SCB13-125 125 340 1850 1.5
    SCB13-160 160 385 2130 1.5
    SCB13-200 200 445 2530 1.3
    SCB13-250 250 515 2760 1.3
    SCB13-315 315 635 3470 1.1
    SCB13-400 400 705 3990 1.1
    SCB13-500 500 835 4880 1.1
    SCB13-630 630 935 5880 0.9
    SCB13-800 800 1095 6960 0.9  

     

     

    6.0

    SCB13-1000 1000 1275 8130 0.9
    SCB13-1250 1250 1505 9690 0.9
    SCB13-1600 1600 1765 11730 0.9
    SCB13-2000 2000 2195 14450 0.7
    SCB13-2500 2500 2590 17170 0.7

    4  SCB14 dry type transformer features:

    1. The SCB14 dry-type transformer has the characteristics of strong short-circuit resistance, small maintenance workload, high operating efficiency, small size, and low noise. It is often used in places with high performance requirements such as fire protection and explosion-proof. It is safe, fire-proof, non-polluting and can be directly run on high-load electricity.
    2. Adopting the best domestic technology, it has high mechanical strength, strong short-circuit resistance, small partial discharge, good thermal stability, high reliability and long service life.
    3. Low loss, low noise, obvious energy saving effect, maintenance-free
    4. Good heat dissipation performance, strong overload capability, and can operate at over capacity for a short time under forced air cooling.
    5. It has certain moisture-proof performance and can operate in harsh environments with high humidity.
    6. Dry-type transformers can be equipped with complete temperature detection and protection systems.
      Model  Rated capacity Connection group label Voltage combination No-load loss (w) Load loss (w) Short-circuit resistance (%))
      HV  tap range LV
      SCB14-30-NX2 30  

       

       

       

       

       

       

      Yyn0

      or

      Dyn11

       

       

       

       

       

       

       

      11

      10.5

      10

      6.6

      6

       

       

       

       

       

       

       

       

      ±5%

      ±2×2.5%

       

       

       

       

       

       

       

       

      0.4

      150 670  

       

       

       

       

       

      4.0

      SCB14-50-NX2 50 215 940
      SCB14-80-NX2 80 295 1480
      SCB14-100-NX2 100 375 1740
      SCB14-125-NX2 125 430 2000
      SCB14-160-NX2 160 495 2370
      SCB14-200-NX2 200 575 2590
      SCB14-250-NX2 250 705 3270
      SCB14-315-NX2 315 785 3750
      SCB14-400-NX2 400 930 4590
      SCB14-500-NX2 500 1070 5530
      SCB14-630-NX2 630 1040 5610
      SCB14-800-NX2 800 1215 6550  

       

      6.0

      SCB14-1000-NX2 1000 1415 7650
      SCB14-1250-NX2 1250 1670 9100
      SCB14-1600-NX2 1600 1960 11050

      5  Summary of SCB18 dry type transformer characteristics:

      Low loss, small partial discharge, low noise, strong heat dissipation ability

      Safe, flame retardant and fireproof, no pollution, can be installed directly in the load center

      Maintenance-free, easy installation, low overall operating cost

      45° fully oblique stepping seam core

      Multi-layer segmented cylindrical high voltage coil

      Longitudinal air channel foil structure low voltage coil

      Sturdy and beautiful protective case

      Complete temperature protection control device